Downgrade or restore factory firmware

Downgrade or restore factory firmware

If you need to downgrade the version or recover the firmware, it's important to consider the type of control board, as flashing methods may differ. For example, boards with Amlogic processors require using an OTG adapter and flashing via the Micro-USB port, while boards with Xilinx and CVITEK processors can be flashed via the SD card slot.

Recovery instructions

  1. Select and download the appropriate firmware for your miner (lists available below)
  2. Format the SD card or USB drive in FAT/FAT32 format
  3. Copy the firmware files from the archive and write them to the SD card or USB drive
  4. Remove the media from your computer and insert it into the powered off miner
  5. Power on the miner and wait for the green LED indicator, which means the procedure completed successfully
  6. Power off the miner and remove the SD card or USB drive
Firmware recovery process

The SD card capacity should be up to 16GB. If you're using a USB drive, its capacity should not exceed 8GB. It's important to use USB 2.0.

If you're unsure about choosing firmware for your control board, refer to the Control Board Types section

IMPORTANT: The installation/recovery process must not be interrupted - by powering off or removing the storage device. This may result in the loss of low-level software. In this case, the control board can only be recovered at a service center.

If the version doesn't change after flashing:

  1. Clean the dust from the SD card slot or USB port
  2. Try using a different storage medium
Firmware files for recovery or downgrading are provided below in this article.

Stock firmware files